What a battery can sell
What ancillary services can a battery sell in Indian power exchanges and interstate system operation?
Indian power exchanges and interstate system operation has 5 ancillary-service products, across 5 families — frequency containment, automatic frequency restoration, manual frequency restoration, reactive power & voltage and black start & restoration: Black Start / System Restoration Service, Primary Reserve Ancillary Service, Reactive Power and Voltage Control, Secondary Reserve Ancillary Service, Tertiary Reserve Ancillary Service. Response timing, direction and eligibility for each are in the cards below, as the official sources state them.
Facts below are stated as the official sources state them. A missing line means the
source does not state that value — never that the value is zero.
Automatic frequency restoration
-
Secondary Reserve Ancillary Service SRAS
operational
Restore frequency and area control after primary response, addressing regional imbalance.
- Direction
- raise; lower
- Expected within
- 30 seconds
- Full activation
- 15 min
- Sustain
- at least 30 min
- Trigger / range
- NLDC activation for sustained frequency/area imbalance and conditions specified in Regulation 8; no universal public Hz threshold.
- Eligibility
- Interstate or intrastate generation, storage or demand response with bidirectional communications, AGC where applicable, metering/SCADA and minimum 1 MW response.
- Typical procurement
- Regional requirement is calculated dynamically by the Nodal Agency.
Provider must begin responding within 30 seconds, deliver the full SRAS obligation within 15 minutes and sustain at least the next 30 minutes.
Manual frequency restoration
Black start & restoration